shunt trip coil rating

What Is A Shunt Trip Breaker & How Does It Work? Detailed Guide

Hello readers welcome to the new post. In this post, we will learn What Is A Shunt Trip Breaker & How Does It Work. The shunt trip breaker is a combination of a shunt trip accessory and a main circuit breaker. it connects to the main breaker for the protection of the electrical system. it also added security to the system since it manually or automatically cut the supply in the circuit. In this post, we will discuss the all details shunt trip breaker and other parameters. So let’s get started What is a shunt trip

Table of Contents

What is a Shunt Trip Breaker?

If the circuit breaker trips it finds faults condition and automatically shuts off the current flow to prevent the circuit from overheating.  The shunt trip breaker is an optional device for a circuit breaker that helps to trip the breaker remotely in any instant or automatically in case of surge saving any damage and instrument damage.

There are 2 main types of shunt trip breakers first one is manual and the second one is automatic.

Manual witches help to off the breaker externally with the use of the remote button. Automatic switch off power when detecting surges from the external power supply.

What Is A Shunt Trip Breaker

 How Does a Shunt Trip Breaker Work?

Normally the current passes through the circuit breaker. But if these currents become high surges, the larger surge of power changes the electromagnet below the breaker switch, tripping the cutting power and switch.

The shunt trip breaker offers extra techniques to charge the electromagnet and trip switch, helping remote or automatic power shutoff. Some hunt trips are connected to an external power supply.  When power surges get that source, signal flow from shunt trip to the breaker, mechanical cutting power.

The shunt trip can make a connection with the remote switch outside the building. Pushing the button on the switch sends a surge through shunt trip wiring and off the power.

 Components of  Shunt Trip Breaker

Read more  Top Reasons Why Electric Outlet Stopped Working Breaker Not Tripped?

A shunt trip breaker comes with differnt components:

  • The frame of the shunt trip circuit breaker works as an external protective housing and covers all inner components. it is made with the use of durable materials like metallic that help to avoid damage to sensitive inner circuits.
  • Contacts are the main part of the circuit breaker that carries electric current. in a shunt trip circuit breaker, there are two types of contacts, main contacts, and auxiliary contacts. The main contact is used for normal power transmission, and auxiliary contacts are used for connecting the external control system

Operating Mechanism:

  • The working phenomena in shunt trip circuit breakers help to open and close contacts. it comes with latch releases and trip units. The latch releases are used for maintaining contacts in the closed position until the trip mechanism works. The trip unit detects abnormal electrical conditions and starts the tripping process.

Electromagnet:

  • At the core of the shunt trip circuit breaker electromagnet exists, which is important for working. If the external signal gets, the electromagnet activates and produces a magnetic field. This field work on latch releases resulted to open circuit breaker contacts.
  • It is the main part of the shunt trip breaker that operates uniformly with an electromagnet. its working is to get an external signal and convert into electrical energy. this energy is used to producing the field needed for tripping breaker.

Why Are Shunt Trip Breakers Important?

irrespective optional nature of the shunt trip breaker, it can be an important safety instrument in a power system. As a result, many engineers use this breaker as a layer of security since they save damage during power surges.

This breaker is good for many fonts but it’s commonly used during fire. By turning off power if a fire breaks out, the electrical hazard is no main risk. Some connections shunt trip to smoke alarm in homes, for power automatically off when detector trigger alarm. It not be good option, since in some conditions smoke alarm gets off due to steam from the shower of smoke from the kitchen

 Applications of Shunt Trip Breakers

  • In commercial buildings like offices, and shopping malls, shunt trip circuit breakers are connected to ensure sure safety of many components and protect them from electrical faults. It also connected with a building management system to help remote operations
  • Industrial facilities mostly work with high-power machines, so electrical safety is needed. Shunt trip breakers are used in such facilities for protection from faults and to reduce the chances of electrical accidents.
  • Laboratories and research facilities also use these breakers since they are equipped with sensitive devices.
  • There is a need for a regular power supply for critical patient care. Shunt trip breakers help to make sure emergency power is constant without any interruption.
  • Data centers come with computing devices and sensitive data. Shunt trip breakers are used to protect these facilities from electrical hazards.

 Advantages of Shunt Trip Breakers

  • The main benefit of a shunt breaker is that it can remotely shut off in case of any fault. It quickly works and disconnects power in fire which helps to avoid damage in the home and protects people.
  • These devices also increase safety levels and security by automating off power to the circuit if there is any fault. it helps to save electrical fires and any other damage.
  • The shunt breaker is easily connected and confined with a power system, so it is easy to install the device in the building.
  • The shunt breaker is a less cost solution for safety measures in buildings and industries. it is less costly to buy and connect and helps to save homes and buildings in the result of high fault.
  • Shunt breakers support many electrical systems and devices so it is versatile devices that are used for the protection of circuits.

 Comparison with Other Circuit Protection Devices

Shunt trip breakers vs. standard circuit breakers.

The basic difference between shunt trip breakers and regular circuit breakers is their function. Regular breakers are manually operated and based on a user-to-flip switch if requried or on current overloading that triggers the unlatching process.

While shunt trip breaker provdies more layers of controls. it can be triggered remotely with the use of a switch or automated system. These features allow them to immediately off power in case of fault.

Shunt trip breakers vs. ground fault circuit interrupters (GFCIs)

GFCI monitors equality between L1 and L2, if there is more than predefined difference in trips. The shunt breaker is a combination type device that combines in regular breaker with its regular function trip it has a remote control to trip breaker.

Ground fault breakers monitor current on neutral wire flowing back to the neutral bar, the four to six-milliampere different trip breakers, and shunt trip breakers can tripled remotely from other switches or points. In industrial uses, it is used to shut off in emergency condtion, when access to an electrical panel is difficult.

Shunt trip breakers vs. arc fault circuit interrupters (AFCIs)

Shunt Trip Breaker

  • It used for overloading and short protection
  • its working principle is based on thermal magnetic trip
  • Its detection range is 10 to 1000A
  • its response time is 10 to 20 milliseconds
  • It used for arc fault protections
  • It works based on a microprocessor for detecting arcing
  • The detection range is 5 to 6000 A
  • Response time is 10 to 40 milliseconds

What Are 3 Types Of Shunt Trip Breakers?

  • Standard breakers
  • Arc fault circuit interrupter circuit breakers

Shunt trip breaker wiring

Follow these steps for shunt trip breaker wiring.

  • First of all, see the diagram shown below.
  • Arrange requried tools and materials like wire strippers, nuts, and voltage tester.
  • Remove the power and wire that shunt the breaker according to instructions.
  • Again connect power to the circuit and test breaker to check that working well

Diagram of Shunt Trip Breaker Wiring Diagram

Diagram of Shunt Trip Breaker Wiring Diagram

WHICH TYPE OF SHUNT TRIP BREAKER TO USE?

The manual breaker is best to use for small buildings or conditions where any technical staff is available to reset the breaker,. The automatic breaker can be best for larger-size buildings or conditions where there is no option for staff for breaker resetting.

it is also preferred for trigger shunt trip breakers at a distance or remotely. These relays are connected to fire alarm systems and can send a signal to the breaker for tripping if there is any fault.

Read more  How Many Outlets on a 15 Amp Circuit Breaker?

How Many Outlets on a 15 Amp Circuit Breaker?

60 Amp Wire Size – Which AWG is Best for 60 Amp Breaker

Difference Between a Single and Double Pole Breaker

Where is the Doorbell Breaker Located? Easy Way to Findout

Difference Between Fuse and Circuit Breaker

How does a shunt trip breaker work?

The shunt trip is a device in the circuit breaker that mechanically trips the breaker when power is given to shunt trip terminals. Power for shunt trip does not come in breakers, so it provided from an external source

How is a shunt trip breaker wiring?

Make the connection of accurate voltage (120V to 240V for the -1021 suffix) with 2 terminals on the shunt trip. Land with a leg from source contact on one terminal and a neutral wire. (L2 , X2 ) to the other terminal

What is the purpose of a shunt with a relay?

Shunt relays are used to bypass normal controls like switches , dimmers, or panel-mounted relays when employed on an emergency circuit.

What is shunt trip and under voltage?

The shunt trip coil is connected to the breaker to offer a remote trip of the breaker but Undervoltage or no voltae coil is connected to offer automatic tripping when power losses occur or when there is a major voltage dip.

Where is shunt trip used?

The shunt trip helps to remotely and fastly turn off the breaker when needed especially in conditions where safety and speed is important, like during a fire or when there is needed to isolate certain areas of the electrical system without physically going to the breaker

What is the difference between shunt and resistance?

The shunt is an electrical device that produces a low resistance path for current. It helps current to flow to another point in cirucit. Shunts are also referred to as ammeter shunts or current shunt resistors.

What is the purpose of a shunt breaker?

its main purpose is to remotely and fastly turn off  circuit breaker when necessary

Is the shunt resistor AC or DC?

Shunt provdies DC mV signal for driving moving coil ammeter, overlading protection, and control units for high amper range.

Where are shunt trip breakers required?

These breakers are used in commercial  and industrial buildings, also for facilities where safety is a top priority

Why is it called a shunt resistor?

In older circuits, resistors connected in parallel to the ammeter as shunts for expanding the current measuring range called shunt resistors. but now resist used for detection circuit current  collectively referred to as shunt resistors

Why is low resistance called shunt?

When a resistor is connected with another resistor of low value, then the equivalent resistance is less the lowest resistor, that is shunt resistors.

What is another name for a shunt resistor?

Shunts also called ammeter shunts  or current shunt resistors.

What is a unit of shunt resistance?

The unit of shunt resistance is ohm (Ω).

What is shunt resistance formula?

The shunt resistance formula is:

  • Rs is the shunt resistance
  • V is the voltage of the shunt resistor
  • I is the current passing through the shunt resistor

What is shunt release in a circuit breaker?

The shunt releases is opening coil plus release. Thermal trips and electromagnetic trips also use trip units. use a certain voltage to shunt trip the coil, and the breaker will trip and open.

What is the difference between a shunt trip and series trip?

What are the different types of shunt trip breakers, does a shunt trip breaker need a neutral, what is the difference between shunt trip and a shunt close.

When used as a shunt trip the coils trip breaker when a rated voltage is given. When used as shunt close, coils closes breaker when voltae is provided

Share this:

Wholesale PCBs SMT Stencil & PCBA Service Provider

Special offer:$2 for 1-8 layer PCBs 

Sign Up & Get 54$ Coupon

shunt trip coil rating

Author:  Scott Spencer

I am professional content writer have professional degree in engineering. I have worked in different famous companies and also providing technical and seo based services clients all over the world. With that i am sharing my knowledge to engineering and technical students and new learners to enhance their learning and get new ideas in technical fields. Follow him on Twitter and Facebook .

Related Posts

Durable and Aesthetic Furniture

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Save my name, email, and website in this browser for the next time I comment.

Post comment

Galvin Power

Galvin Power is reader-supported. When you buy via our links, we may earn a commission at no cost to you. Learn more

What is a Shunt Trip Breaker and How Does It Work?

Written by  Edwin Jones  / Fact checked by  Andrew Wright

what is a shunt trip breaker

What is a shunt trip breaker? Does it add protection to your electrical system?

The shunt trip breaker is a combination of the shunt trip accessory and the main circuit breaker. This installs on the main breaker to add protection to your electrical system. This adds security to your electrical system as it manually or automatically cuts the electric supply in your circuit.

This accessory can help prevent short circuits and avoid electrical damage should a disaster occur in your home.

Let me tell you more about the shunt trip breaker to help you decide if you need additional protection for your electrical system.

Table of Contents

What is Shunt Trip Breaker and How Does It Work

Where are shunt trip breakers most used, how to install a shunt trip accessory to the breaker.

shunt-trip-relay

You should know that shunt trip breakers are different from GFCI circuit breakers.

The GFCI circuit breaker contains one big white tail wire for neutral connections only. It cannot be connected to any control package because the GFCI circuit breaker is solely designed to detect a sudden electrical surge. It has no other purpose but to cut power in case of a short.

Meanwhile, the shunt trip breaker wiring comprises two wires. One connected to the ground, and another to a control system. The control system can be connected to a sensor or to a manual switch. When activated, the shunt trip accessory will cause the main breaker to trip.

For example, if you install a shunt trip with a smoke detector, it will activate and cut off the power should the smoke sensor trigger. It can also be installed with a remote switch , allowing you to trip your breaker manually.

It is crucial to know the difference between a regular circuit breaker and a circuit breaker installed with shunt trip accessories.

shunt-trip-definition

The shunt trip definition means that it is a way to cut off electrical power through other sensors, not just via thermal activation. Since this is an optional accessory for a circuit breaker, it is not required for a home electrical system.

However, it is recommended for added safety. This is especially true if you’re working with industrial machinery. Furthermore, you can use it as a manual emergency switch to shut down your main breaker.

Before installing a shunt trip, consider its cost and your existing system. You may need to change the breaker panel  and circuit breakers, especially if it is not compatible with shunt trips. You may also need a new line to connect the remote emergency switch to your breaker box.

Generally, most commercial kitchens, elevators, and offices have this shunt trip breaker because it is required. Commercial kitchens use this device in compliance with ANSI/ASME CSD-1, while elevators and escalators comply with ASME A17.1. These codes refer to the controls and safety standards provided by ASME’s.

This question is a topic of discussion among Reddit members as well. Join the conversation here:

Found at a dominos by u/Guilty_Sympathy_496 in electricians

Mostly, installing a shunt trip relay requires that the breaker and the shunt be from the same maker. Also, not all breaker models are compatible with this accessory.

Once you’re sure that your system can take a shunt trip accessory, installation is pretty much straightforward. You can watch this video by Aaron CBIONE for some tutorials.

Note: Every circuit breaker comes with different instructions. It would depend on the brand and model of the breaker .

However, the critical part of every installation is that you need to connect the shunt to your sensor. You may need a shunt trip breaker diagram as a reference to ensure correct installation.

Also, check the brand and model of your breaker before proceeding with the installation. Some makers only allow a factory install of the shunt trip and other accessories. DIY installation may void the warranty of your breakers. It’s best to read up on the manual or consult an electrical professional before making any changes.

What is a shunt trip breaker? The shunt trip is an optional accessory for a circuit breaker for added protection to your system. It is designed to connect to a secondary sensor. It will trip the breaker automatically if the sensor is triggered. It can also be activated via a remote switch that you can install.

Do you think that a circuit breaker is enough to protect your investment? Or do you want an additional layer of protection for your electrical circuit? If you’re not decided yet, reach out to me in the comments section below, and I will be happy to help you.

Andrew-Wright

I am Andrew Wright. With 8 years of experience designing, installing, and maintaining electrical power systems. I love my job, and I have always wanted to offer others the necessary help so they can take care of their houses.

BCS Logo

  • Our Core Values
  • Video Learning
  • Capabilities
  • Air Breakers
  • Insulated Case
  • Switchgear Repair
  • Switchgear Parts
  • Vacuum Breakers
  • Switchboard Manufacturing
  • Power Panelboards
  • Switchgear Rental
  • Power Transformer Rental
  • Powder Coating
  • Replacement Parts
  • Molded Case
  • Air Contactors
  • Vacuum Contactors
  • Switchgear Safety
  • Testing Switchgear
  • Content Library
  • 24/7 Customer Service
  • Credit Application
  • Switchgear Project Gallery
  • Social Archives

Shunt Trip Parts In Stock for Remote Tripping Your Circuit Breakers

Remotely trip and disconnect power to a specific circuit, safely and remotely trip circuit breakers.

A shunt trip is an electrical circuit’s equivalent of a heroic maneuver. Consider a circuit breaker to be a guard for your electrical system. Its purpose is to keep things from going crazy if there is too much power present.

Enter the shunt trip, which functions similarly to the guard’s remote control. When you push a button on this remote, a particular coil inside it becomes energized and generates a magnetic field. This magnetic field communicates with the circuit breaker and nudges it, saying, “Hey, time to take a break!”

The circuit breaker receives the signal and says, “Alrighty, shutting down now!” It just opens its connections and cuts off the electricity flow. This comes in handy when you need to rapidly turn off the power from a distance. Consider it a safety switch that you can activate even if you aren’t directly next to the breaker.

In other words, a shunt trip is a remote-controlled means to cause a circuit breaker to trip by utilizing a magnetic magic trick. It’s useful for keeping things secure without having to go around flipping switches.

Are you looking for Shunt Trip parts? We made a video inside our Switchgear and Circuit Breaker Parts Warehouse. This particular video is about Siemens/Allis Chalmers MA Series circuit breaker parts. Below is a little more about a shunt trip for a MA-this breaker’s specifications.

Voltage Rating: The “4.76KV” indicates the voltage rating of the circuit breaker. It suggests that the breaker is designed to handle systems with a voltage of 4.76 kilovolts (kV).

Current Rating: The “1200A” indicates the current rating of the circuit breaker. It suggests that the breaker can carry a continuous current of up to 1200 amperes without tripping.

Operating Mechanism: The “EO/DO” likely refers to the operating mechanisms of the circuit breaker. “EO” stands for “Electrical Operation,” meaning the breaker can be controlled remotely using an electrical signal. “DO” stands for “Manual Operation,” indicating that there’s a manual mechanism to operate the breaker as well.

This video is about Siemens/Allis Chalmers MA Series circuit breaker parts. Below is a little more about this breaker’s specifications. Voltage Rating: The “4.76KV” indicates the voltage rating of the circuit breaker. It suggests that the breaker is designed to handle systems with a voltage of 4.76 kilovolts (kV).

Current Rating: The “1200A” indicates the current rating of the circuit breaker. It suggests that the breaker can carry a continuous current of up to 1200 amperes without tripping. Operating Mechanism: The “EO/DO” likely refers to the operating mechanisms of the circuit breaker. “EO” stands for “Electrical Operation,” meaning the breaker can be controlled remotely using an electrical signal. “DO” stands for “Manual Operation,” indicating that there’s a manual mechanism to operate the breaker as well.

Interrupting Capacity: This specification refers to the maximum fault current that the circuit breaker can safely interrupt without causing damage. It’s crucial for ensuring the protection of the electrical system. Tripping Characteristics: Different circuit breakers can have various tripping characteristics, such as instantaneous, short-time delay, and long-time delay trips. These settings determine how quickly the breaker will trip in response to different levels of fault currents.

Physical Dimensions: The physical size and dimensions of the circuit breaker are important to ensure that it fits within the designated switchgear or electrical enclosure. Environmental Ratings: These ratings indicate the operating conditions the circuit breaker is designed for. This includes factors such as temperature range, humidity, altitude, and indoor/outdoor usage.

Accessories: Circuit breakers can come with various accessories like shunt trips, auxiliary switches, ground fault protection, and more. These accessories enhance the functionality and safety of the breaker. Standards Compliance: The circuit breaker should meet relevant industry standards, such as those set by organizations like ANSI, IEC, or IEEE.

Documentation: The manufacturer should provide detailed documentation that includes installation instructions, operation guidelines, maintenance procedures, and troubleshooting information. For accurate and updated information on the MA-250C Allis-Chalmers 1200A 4.76KV EO/DO Air Circuit Breaker, reach out to the manufacturer directly or consulting official product manuals and specifications.

Cody Whisenhunt, President, BCS Switchgear

BCS Switchgear is an industry leader in new and obsolete electrical control and distribution equipment. Since 1997, BCS has been servicing customers to extend electrical life of low and medium voltage electrical power equipment.

Cody can be reached by email: [email protected]

  • Privacy Policy
  • Terms & Conditions

fish

888- 599- 0486

shunt trip coil rating

GET A QUOTE

Please fill out the appropriate information below.

Name: Name: Name: Message:

Shunt trips

shunt trip coil rating

Are you looking for support or purchase information?

Main benefits.

shunt trip coil rating

Right mounted version suitable for both MCBs and RCDs and left mounted version for MCBs

shunt trip coil rating

Time-saving mounting through the fixed snap-hooks for the right mounted version and through the connection links on the left mounted version

shunt trip coil rating

Combination with auxiliary and signaling contacts as well as with the Motor Operating Devices (MOD) and Auto-Reclosing units (AR)

Main features

  • Pass-through for pin busbars on top and bottom to enable installation with busbar
  • QR code printed on the front of the product to easily access product data
  • Wiring cross sections: 1 wire 0,75...2,5mm², 2 wires max. 2 x 1,5mm²
  • Extended voltage range for A1 version. From 12…60 V AC/DC to 12…110 V AC/DC 

Products and Documentation

  • End of Life Instruction S3C-Axx ( en - pdf - Instruction )
  • 2D drawing S3C-A1L S3C-A2L ( en - pdf - Drawing )
  • 2D drawing S3C-A1 S3C-A2 ( en - pdf - Drawing )
  • Technical data sheet S3C ( en - pdf - Data sheet )
  • CSA certificate of S3C shunt trips ( en - pdf - Certificate )
  • UL certification S3C shunt trips ( en - pdf - Certificate )
  • UKCA declaration S3C/S2C shunt trips ( en - pdf - Declaration of conformity )
  • Cross reference S3C shunt trips ( en - xlsx - Reference list )
  • Instruction Manual S3C-A1L, S3C-A2L ( en - pdf - Manual )
  • Instruction Manual S3C-A1, S3C-A2 ( en - pdf - Manual )
  • EU Declaration of Conformity S2C-A1, S2C-A2, S2C-A1L, S2C-A2L, S2C-A1U, S2C-A2U, S2C-A1T, S2C-A2T, S2C-A1TL, S2C-A2TL, S2C-A1TU, S2C-A2TU, S3C-A1, S3C-A2, S3C-A1L, S3C-A2L ( en - pdf - Declaration of conformity )
  • 3D data S3C-AxL ( en - stp - CAD outline drawing )
  • 3D data S3C-Ax ( en - stp - CAD outline drawing )

Submit your inquiry and we will contact you

Quickly find an ABB channel partner

  • Middle East and Africa
  • Asia and Oceania
  • Global - English
  • Austria - German
  • Belgium - Dutch | French
  • Bulgaria  - Bulgarian
  • Croatia - Croatian
  • Czech Republic - Czech
  • Denmark - Danish
  • Estonia - Estonian
  • Finland - Finnish
  • France - French
  • Germany - German
  • Greece - Greek
  • Hungary - Hungarian
  • Ireland - English
  • Italy - Italian
  • Latvia - Latvian
  • Lithuania - Lithuanian
  • Luxembourg - French
  • Netherlands - Dutch
  • Norway - Norwegian
  • Poland - Polish
  • Portugal - Portuguese
  • Romania - Romanian
  • Russia - Russian
  • Serbia - Serbian
  • Slovakia - Slovakian
  • Slovenia - Slovenian
  • Spain - Spanish
  • Sweden - Swedish
  • Switzerland - French | German | Italian
  • Turkiye - Turkish
  • United Kingdom - English
  • Argentina - Spanish
  • Aruba - Spanish
  • Bolivia - Spanish
  • Brazil - Portuguese
  • Canada - English | French
  • Chile - Spanish
  • Colombia - Spanish
  • Costa Rica - Spanish
  • Dominican Republic - Spanish
  • Ecuador - Spanish
  • El Salvador - Spanish
  • Guatemala - Spanish
  • Honduras - Spanish
  • Mexico - Spanish
  • Panama - Spanish
  • Peru - Spanish
  • Puerto Rico - Spanish
  • United States of America - English
  • Uruguay - Spanish
  • Algeria - English | French
  • Angola - English | French
  • Bahrain - English | French
  • Botswana - English | French
  • Cameroon - English | French
  • Côte d'Ivoire - English | French
  • Egypt - English | French
  • Ghana - English | French
  • Israel - Hebrew
  • Jordan - English
  • Kenya - English | French
  • Kuwait - English
  • Lebanon - English
  • Madagascar - English | French
  • Mali - English | French
  • Mauritius - English | French
  • Morocco - English | French
  • Namibia - English | French
  • Nigeria - English | French
  • Oman - English
  • Pakistan - English
  • Palestine - English
  • Qatar - English
  • Saudi Arabia - English
  • Senegal - English | French
  • South Africa - English
  • Tanzania - English | French
  • Tunisia - English | French
  • Uganda - English | French
  • United Arab Emirates - English
  • Zambia - English | French
  • Zimbabwe - English | French
  • Australia - English
  • Bangladesh - English
  • China - Chinese | English
  • India - English
  • Indonesia - English
  • Japan - Japanese
  • Kazakhstan - Russian
  • Malaysia - English
  • Mongolia - Mongolian | English
  • New Zealand - English
  • Philippines - English
  • Singapore - English
  • South Korea - Korean
  • Sri Lanka - English
  • Taiwan (Chinese Taipei) - Chinese - Traditional
  • Thailand - English
  • Vietnam - English

abb.com privacy settings

Our website uses cookies which are necessary for running the website and for providing the services you request. We would also like to set the following optional cookies on your device. You can change these settings any time later by clicking "Change cookie settings" at the bottom of any page. For more information, please read our privacy notice.

We collect statistics to understand how many visitors we have, how our visitors interact with the site and how we can improve it. The collected data does not directly identify anyone.

We store choices you have made so that they are remembered across visits in order to provide you a more personalized experience.

Your browsing behavior is tracked across websites by advertising and social network service providers. You may see tailored advertising and content on other websites based on your browsing profile.

Preferences​

Advertising and tracking

Popular links

  • ABB Connect
  • ABB Electrification
  • Where to buy
  • Mission to Zero
  • ABB Ability
  • Supplying to ABB
  • Customer events
  • Investor events
  • Media events
  • Get custom product tools and services
  • Access training
  • Manage support cases
  • Create and manage your orders (authorised partners only)

Welcome to the Schneider Electric Website

S29390 Product picture Schneider Electric

Circuit breaker accessory, PowerPacT H/J/L, shunt trip, 24VDC

Sustainability.

EU RoHS Declaration

China RoHS declaration

Product out of China RoHS scope. Substance declaration for your information

shunt trip coil rating

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

IMAGES

  1. Schneider Electric Shunt Trip Ezdsht200ac Shunt Coil

    shunt trip coil rating

  2. STCRK120VAC

    shunt trip coil rating

  3. MCCB Breaker Shunt Trip and Indication Lamp Connection

    shunt trip coil rating

  4. How to wire the circuit breaker shunt trip?

    shunt trip coil rating

  5. 220V Shunt Trip For 3 & 4P MCCB 16 to 250A

    shunt trip coil rating

  6. What is a Shunt Trip Breaker and How Does It Work? Best Answer

    shunt trip coil rating

VIDEO

  1. shunt release coil

  2. SHUNT COIL

  3. shunt Release coil testing how do work

  4. Shunt Trip

  5. Vacuum Circuit Breaker

  6. !! shunt trip unit وفيما تستخدم وكيفية تركيبها !! MCCB Shunt Trip Unit

COMMENTS

  1. PDF Shunt trip safety switch

    Standard features. Heavy-duty safety switch design with integrated shunt trip module. Visible means of disconnect—visible blade. 30-1200 A (240-600 Vac) NEMA® Type 1, 3R, 12, 4, 4X. Horsepower ratings same as standard safety switches. Maximum response time of 50 ms.

  2. PDF Instructions for Undervoltage Release, Shunt Trip, and ...

    Table 3. Overcurrent Trip Switch Ratings. Control Voltage Frequency Contact Rating (Amperes) 250 50 - 60 Hz 10 125 DC 0.5 250 DC 0.25 Section 2: Installation of Undervoltage Re-lease and/or Shunt Trip in Left Accessory Tray Proceed with the following 13 steps: Step 1: Remove the four screws holding the front cover in place (two on each side of ...

  3. What Is A Shunt Trip Breaker & How Does It Work? Detailed Guide

    The shunt trip breaker is a combination of a shunt trip accessory and a main circuit breaker. it connects to the main breaker for the protection of the electrical system. it also added security to the system since it manually or automatically cut the supply in the circuit. In this post, we will discuss the all details shunt trip breaker and ...

  4. PDF Enhance safety and improve equipment performance with shunt trip and

    B Shunt trip switch provides solenoid/coil to facilitate shunt trip, specific relay and applicable power supply provided by others. Shunt trip safety switch. Eaton is a registered trademar ... Shunt trip safety switch—240 Vac and 600 Vac—dimensions and ratings Ampere rating Fuse class A Number of poles Enclosure dimensions B, exterior in ...

  5. Shunt Trip device

    RATING MAX. INRUSH CURRENT TEYXS1 24VAC 4.6A TEYXS2 48VAC 2.4A TEYXS3 120VAC 1.0A TEYXS4 240/277 VAC 0.4A TEYXS5 12VDC 7.5A TEYXS6 24VDC 4.6A ... "OFF" position shunt trip coil should show open. STEP7 LOCATION OF LABELS Rating Label Location Pastethe Rating Label on theBase as shown inthe

  6. PDF fusible shunt trip switch

    molded case switch is an electromagnet (shunt trip coil), controlling a spring-loaded conductive strip which maintains continuity between the ... *Neutral lug rating should be greater than or equal to the switch ampere rating. For 200% lug over sizing, select next higher rating. N4 is suitable for 200% over sizing at 400A.

  7. GEH INSTRUCTIONS Power Break® II Circuit Breaker Accessories Shunt Trip

    PM Trip Unit.If a Shunt Trip with Lockout has been installed, continue with the following steps:5. After the breaker has t. ipped and with the power still applied to the Shun. T. ip with Lockout, attempt to close the breaker. The breaker should not close nor attempt to close.6. If a MicroVersaTrip Pl. s.

  8. PDF Eaton s heavy duty safety switches with shunt trip capability remote

    2 Technical Data TD008003EN Effective September 2014 Shunt trip safety switch EATON www.eaton.com Standards compliance • UL® 98 file number E5239 (600 Vac maximum) • CSA® C22.2 No. 4 file number LL69743 (600 Vac maximum) • UL 98B—contact factory for specific file information (1000 Vdc maximum) • UL 50 • NEMA KS-1 Table 1.

  9. Standard tripping schemes and trip circuit supervision schemes ...

    Standard tripping schemes and trip circuit supervision ...

  10. PDF SHUNT TRIP OPERATORS

    SHUNT TRIP OPERATORS suffix -ST FEATURES: 6208 COMMERCIAL ROAD CRYSTAL LAKE, IL 60014 PHONE: (815) 459-6900 FAX: (815) 455-7788 EASE OF OPERATION ... Trip at 75% of coil rating; trip at 55% of coil rating if intended for use with ground fault sensing equipment. 3 break operations at 10 times rated current, at rated voltage; 3 break ...

  11. What is a Shunt Trip Breaker and How Does It Work?

    The shunt trip breaker is a combination of the shunt trip accessory and the main circuit breaker. This installs on the main breaker to add protection to your electrical system. This adds security to your electrical system as it manually or automatically cuts the electric supply in your circuit. This accessory can help prevent short circuits and ...

  12. STCRK120VAC

    STCRK120VAC. Eaton Shunt trip coil data, 120V coil voltage, 50/60 Hz frequency rating, 66V minimum operating voltage, 0.05 seconds response time, 260 Vac rms minimun voltage. Eaton's mission is to improve the quality of life and the environment through the use of power management technologies and services. We provide sustainable solutions ...

  13. Shunt trip voltage

    Applying voltage to the shunt-trip coil causes the breaker to trip. That voltage needs to be momentary because you can burn up the shunt-trip coil. So whatever scheme you use to trip the breaker, the voltage cannot be sustained after the breaker trips hence the recommendation to use the breaker itself to supply the control voltage.

  14. Shunt trips S2C-A1, S2C-A2, S2C-A1L, S2C-A2L, F2C-A1 and F2C-A2

    Product life cycle announcement. In accordance with the ABB global strategy, the Shunt trips S2C-A1, S2C-A2, S2C-A1L, S2C-A2L, F2C-A1 and F2C-A2 are in the Limited Phase of the life cycle management process. These series will enter the classic phase on April 1st , 2024 . For process details, please visit.

  15. PDF Technical data Shunt trips/Undervoltages

    opening and closing (ms) 100This unit is permanently supplied on stand by, a control is applied by means of. Contact characteristics: Voltage AC/DC=24V Current 50 mA. ical operator, Ts3Rated Voltage ACDCThis unit is permanently supplied on stand by, a control is applied by means of.

  16. Shunt Trips for Remote Circuit Breaker Tripping

    Below is a little more about a shunt trip for a MA-this breaker's specifications. Voltage Rating: The "4.76KV" indicates the voltage rating of the circuit breaker. It suggests that the breaker is designed to handle systems with a voltage of 4.76 kilovolts (kV). Current Rating: The "1200A" indicates the current rating of the circuit ...

  17. What is a Shunt Trip MX used for?

    A Shunt Trip coil is used to remotely trip a circuit breaker and some switch disconnectors. Schneider Electric uses the abbreviation MX or iMX for Shunt Trip coils. A Shunt Trip coil has to have a voltage applied to it to trip the device. An example of an application for a Shunt Trip would be for load shedding.

  18. STCRK120VAC

    Eaton Shunt trip coil data, 120V coil voltage, 50/60 Hz frequency rating, 66V minimum operating voltage, 0.05 seconds response time, 260 Vac rms minimun voltage ... Eaton shunt trip coil replacement kit. Catalog Number. STCRK120VAC. UPC. 786685830322. Product Length/Depth. 2 in. Product Height. 1.5 in. Product Width. 1.7 in.

  19. Shunt trips

    Shunt trips. Shunt trips are used to remote opening of the device when a voltage is applied. Shunt trips use a coil like MCBs for tripping. To trip a shunt it is necessary to choose the right voltage and make sure the corresponding Ibmax is provided by the power supply used.

  20. MX shunt trip release, Compact NSX, PowerPact Multistandard, EasyPact

    Schneider Electric India. LV429387 - MX shunt trip release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 220 to 240 VAC 50/60 Hz, 208 to 277 VAC 60 Hz.

  21. STCRK480VAC

    General specifications. Eaton shunt trip coil replacement kit. STCRK480VAC. 786685830346. 4.75 in. 2 in. 3.75 in. 3.5 lb. Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.

  22. Safety switches

    Eaton's shunt trip safety switches, a market exclusive, provide remote switching and visible means of disconnect for commercial and industrial applications. In addition, the shunt trip technology enhances safety by providing a means to open a safety switch electronically. This product line provides additional code compliant solutions with optional protection schemes including arc energy ...

  23. Circuit breaker accessory, PowerPacT H/J/L, shunt trip, 24VDC

    Green Premium TM label is Schneider Electric's commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO 2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret ...